- Home
- ยป
- Products & Services
- »
- Gas Detectors
Gas Detectors
Honeywell XCD Gas Detector
Product Brochure
Gas Type | Combustible Gas |
Brand | Honeywell |
Model Name/Number | Honeywell XCD |
Usage/Application | Multipurpose |
Temperature Range | 40oF to +149oF (-40oC to +65oC) |
Weight (approx) | Aluminium Alloy LM25: 4.4lbs, 316 Stainless Steel: 11lbs |
Input Voltage Range | 16 to 32VDC (24VDC nominal) |
Communication | RS485 |
Specifications:
•Communication: RS485
•Input Voltage Range: 16 to 32VDC (24VDC nominal)
•Weight (approx): Aluminium Alloy LM25: 4.4lbs, 316 Stainless Steel: 11lbs
•Temperature Range: 40oF to +149oF (-40oC to +65oC)
Toxic Gas Detector
Detector Type | Portable Single Gas |
Name of Gases Detected | nil |
Brand | Drager |
Model | nil |
Power Source | Plug-In |
Display Type | Analog |
Features:
- High power efficient
- Accurate dimension
- Perfect finish
IR Gas Detector
Detector Type | Portable Single Gas |
Brand | Drager |
Power Source | Plug-In |
Minimum Detectable Concentration | nil |
Input line signal | nil |
Terminal Block Plugs | nil |
Country of Origin | Made in India |
Honeywell Touchpoint Gas Detectors
Brand | Honeywell |
Humidity | 10 to 90%RH (non condensing) |
Display Type | Digital |
Temperature | -10 DegreeC to +40 DegreeC / 14 DegreeF to 104 DegreeF |
Pressure | 90-110kPa |
Storage Temperature | -40 DegreeC to +80 DegreeC |
Specifications:
•Temperature: -10°C to +40°C / 14°F to 104°F
•Humidity: 10 to 90%RH (non condensing)
•Pressure: 90-110kPa
•Storage Temperature: -40°C to +80°C
XCD Gas Detector
Brand | Honeywell |
Detector Type | Portable Single Gas |
Minimum Detectable Concentration | nil |
Input line signal | nil |
Terminal Block Plugs | nil |
Power Source | Plug-In |
Country of Origin | Made in India |
- Input Voltage Range: 16 to 32VDC (24VDC nominal)
- Max Power Consumption: Power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W Maximum and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
- Communication: RS485, MODBUS RTU
Honeywell Gas Detector
Brand | Honeywell |
Detector Type | Portable Single Gas |
Gas Type | Combustible Gas |
Power Source | Plug-In |
Usage/Application | Industrial |
Temperature Range | 600 |
Honeywell Midas Gas Detector
Repeatability | < +- 10% of measured value |
Brand | Honeywell |
Linearity | < +- 10% of measured value |
Operating Humidity | 20 to 90% RH |
Response Time | < 5 seconds |
Operating Pressure | 90 to 110kPa |
Specifications:
•Repeatability:< ± 10% of measured value
•Linearity:< ± 10% of measured value
•Response Time:< 5 seconds
•Operating Humidity:20 to 90% RH
•Operating Pressure:90 to 110kPa
Watch Gas UNI Sustainable
Product Brochure
Humidity | 5% ~ 95% RH (Non-condensing) |
Response Time | 15 sec (CO/H2S/O2) Others gases vary (technical note 4: Sensor Technical Data Summaries) |
Sensor Life | CO/H2S: 5 years Other sensors: 1 to 2 years as per warranty |
Battery Type | Replaceable 3.6V AA Lithium battery for 3 years of operation |
The UNI Sustainable is a sustainable single gas detector that offers a simple portable solution for a wide array of toxic gases and O2 (oxygen) applications.
- 28 sensor options – 31 models available;
- Between 2 and 5 year of operation time, depending on the sensor;
- Large LCD, 30% larger than most gas detectors;
Gas Detector
Detector Type | Portable Single Gas |
Brand | Drager |
Power Source | Battery |
Minimum Detectable Concentration | nil |
Input line signal | nil |
Terminal Block Plugs | nil |
Country of Origin | Made in India |
Features:
- High performance
- Optimum detection
- Simple functionality
Specifications:
Sensors | Measuring range | Operating Temperature |
Ammonia NH3 | 0-150 ppm | -20±50°C |
Hydrogen cyanide HCN | 0-20/100 ppm | -20±50°C |
Chlorine Cl2 | 0-5 ppm | 20±50°C |
Carbon monoxide CO | 0-300 ppm | -20±50°C |
Oxygen O2 | 0-35 % | -20±50°C |
Additional Information:
- Item Code: Statox-505
IR Gas Detector
Brand | Honeywell |
Detector Type | Portable Single Gas |
Minimum Detectable Concentration | nil |
Input line signal | nil |
Power Source | Plug-In |
Country of Origin | Made in India |
Watch Gas Poli Multi Gas Detector
Product Brochure
Pump | Yes |
Humidity | 5% ~ 95% RH (Non-condensing) |
Response Time | Sensors: 15 seconds (LEL/CO/H2S/O2) Others gases vary (technical note 4: Sensor Technical Data Summa |
The WatchGas POLI in pumped version is an advanced instrument with an integrated pump that enables a full range of sensors for a variety of applications, including confined space entry. The POLI in diffuse detection version is a multigas detector that is ideally suited for worker safety monitoring in hazardous locations.
- Available in diffusion- or pumped version;
- Man Down Alarm with real-time remote wireless notification;
- IP-65 (pumped versions) and IP-67 (diffusion versions);
- With water and dust resistant case.
Watch Gas Air Watch Flexible Gas Detection
Product Brochure
Pump | Yes |
Humidity | 0 - 95% RH, non-condensing |
The AirWatch is your safe area solution for the monitoring of various gases. Based on the measurement values and alarms, equipment is switched on or off, data is logged and optionally employees are remotely informed of the gas concentrations present.
- Functions in standalone mode or as part of a mesh network;
- Automatically switches pumps, on/off buttons, ventilation, etc.;
- Developed for demanding environments;
- Can be used inside and outside;
Watch Gas XDIwin-F1 Hazardous Area Gas detector
Product Brochure
Humidity | 5 to 95% RH (Non-condensing) |
The XDI Gas Sensor is capable of utilizing a wide range of sensor cell types offering an unmatched number of configurations allowing for a simple stand-alone 4~20mA transmitter.
- Explosion-proof
- Rugged and reliable
Watch Gas -Combi Gas Detection System
Product Brochure
Humidity | 0-95 non condensing |
Combi has been designed to operate in the full range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing.
- 1 to 64 addressable sensors;
- 1 – 8 plugin direct catalytic cards;
- Single 4 core sensor network (addressable);
Watch Gas SIL Point Toxic Gases
Product Brochure
Humidity | 20 to 90% RH (not condensing) |
Certification | IECEx BSV 16.0038 X (electrical Ex protection), IEC 60079-0, -1 (Ex db) |
Warranty | 1 year on sensor (not if poisoned or overloaded), 2 years on device |
Microprocessor based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapours by means of a catalytic sensor element (Pellistor).
Portable Gas Detectors
Features:
- Hassle-free detection
- Smooth operation
- Simple functionality
CO2 Gas Detector
Minimum Order Quantity: 1 Piece
Detection limit | 0,03 Vol.% CO2 |
Repeatability | <+-2% |
Warm up time | 20 s |
Specifications reached | after 30 min |
Humidity | 0 - 99% r.F |
Measuring range | 0-2 or. 0-5 Vol.% |
Response time | t50 < 15s,t90 < 45s |
Operating temperature | 20 DegreeC to +60 DegreeC |
Country of Origin | Made in India |
- Measuring range 0-2 or. 0-5 Vol.%
- Detection limit 0,03 Vol.% CO2
- Repeatability: <±2%
- Display LED: Three digit
- Response time: t50 < 15s, t90 < 45s
- Warm up time: 20 s
- Specifications reached:after 30 min
- Operating temperature: 20°C to +60°C
- Humidity: 0 - 99% r.F
Additional Information:
- Item Code: Statox-501-IR
Watch Gas Single Gas Detector
Product Brochure
Humidity | 5 ~ 95 %RH (Non-condensing) |
Response Time | H2S, CO, O2: < 10 sec SO2: <55 sec Other sensors may vary |
The SST1 Serviceable offers one of the most cost-effective solutions on the market. With its 3-year replaceable battery and solid polymer sensor technology the SST1 offers a compact and modular design, while not compromising on its ruggedness.
- TWA & STEL Alarms
- NFC and WatchGas Application
- 3-year battery life based on alarms
- Serviceable Battery and Sensors
VOC Detector
Detector Type | Portable Single Gas |
Brand | Drager |
Power Source | Plug-In |
Accuracy | nil |
Sensitivity | nil |
Pump | Yes |
Display Type | Digital,Analog |
Specifications:
- Detectable Gases: Volatile substances with a ionisation potential below 10,6 eV
- Measuring programs: 0 – 10.0, 0 - 100, 0 - 1000, 0 – 10,000 ppm
- Measuring principle: Photo - ionisation
- Operating temperature:-30 - + 60°C
- Humidity: 0 - 95 % r. H non condensing
- Pressure: 700 - 1300 hPa
Fixed Toxic Gas Detection System
Brand | Honeywell |
Detector Type | Portable Single Gas |
Minimum Detectable Concentration | nil |
Input line signal | nil |
Terminal Block Plugs | nil |
Power Source | Plug-In |
Country of Origin | Made in India |
- Gas cell path: 6m or 10cm path
- Lower detection limit:~ 1.0ppm for 6m path cell
- Scanning rate:15 sec per point
Additional Information:
- Pay Mode Terms: T/T (Bank Transfer)